Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +43 1 706 45 25-0

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Mounting method:
Coating contact:
Family construction form:
Material contact:
No. of poles:
Side 2
Stripping length (jacket):
Electrical data | Supply
Operating voltage AC min.:
Operating voltage AC max.:
Operating voltage DC min.:
Operating voltage DC max.:
Current operating per contact max.:
Diagnostics
Status indication LED:
Installation | Connection
Stripping length (jacket):
Family construction form:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Additional suppressor:
Mechanical data | Material data
Material gasket:
Material housing:
Mechanical data | Mounting data
Looking techniques:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Printing color of wire insulation:
Printing spacing of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Filler:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Printing color of wire insulation:
Printing spacing of wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Electrical data | Cable
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
Packaging unit:
customs tariff number:
GTIN:
Move
Valve plug MDC06-4s with cable Valve plug MDC06-4s with cable
RADOX EM 104 4x0.75 bk 10m
Weight: 0.711 kg
Art.No.: 7080-72161-R231000

not available
Move
Valve plug MDC06-4s with cable Valve plug MDC06-4s with cable
RADOX EM 104 4x0.5 bk 10m
Weight: 0.523 kg
Art.No.: 7080-72161-R031000

Contact Us for Availability
10 m
10 m
inserted
inserted
nickel plated
nickel plated
MDC
MDC
Copper alloy
Copper alloy
4
4
40 mm
40 mm
6 V
6 V
230 V
230 V
6 V
6 V
230 V
230 V
8 A
8 A
no
no
40 mm
40 mm
Amphenol AT06-4S
Amphenol AT06-4S
IP68
IP68
inserted, screwed
inserted, screwed
3
3
2,5 kV
2,5 kV
I
I
without components
without components
Silicon
Silicon
PA
PA
Snap-in connector
Snap-in connector
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
R23
R03
black (white isolation)
black (white isolation)
-
15 mm
black
black
-
-
-
1
4 wires twisted
4 wires twisted
yes
-
white 1, white 2, white 3, white 4
white 1, white 2, white 3, white 4
69,3 g/m
50,6 g/m
Radox EM 104
Radox EM 104
-
-
5,6 mm
5 mm
± 5 %
± 5 %
Radox EI 303
Radox EI 303
4
4
1,62 mm
1,42 mm
± 5 %
± 5 %
-
-
black (white isolation)
black (white isolation)
-
15 mm
19
19
0,23 mm
0,18 mm
0,75 mm²
0,5 mm²
copper stranded wire, tinned
copper stranded wire, tinned
1000 V
1000 V
600 V
600 V
to DIN VDE 0298-4
to DIN VDE 0298-4
9,6 A
7,2 A
26 Ω/km @ 20 °C
40,1 Ω/km @ 20 °C
3,5 kV
3,5 kV
3,5 kV
3,5 kV
-50 °C
-50 °C
120 °C
120 °C
-25 °C
-25 °C
90 °C
90 °C
-
-
-
-
-
-
-
-
-
-
IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
DIN EN 60811-404 | Good, application-related testing
3 x Outer diameter
3 x Outer diameter
4 x Outer diameter
4 x Outer diameter
27279218
27279218
27279218
-
27279218
27279218
27279218
27279218
27060312
27060311
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
1
1
85444290
85444290
4048879743662
4048879754309
* plus VAT, plus shipping