Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +43 1 706 45 25-0

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Coding:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Operating voltage AC (UL-listed):
Operating voltage DC (UL-listed):
Current operating per contact max.:
Installation | Connection
Mounting set:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data | Material data
Coating locking:
Coating of fitting:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Amount stranding (type 2):
Stranding (type 2):
Banding:
wire arrangement:
Mechanical data | Cable
Traversing distance (C-track):
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
Packaging unit:
customs tariff number:
GTIN:
Approvals
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Move
M12 female 90° A-cod. with cable M12 female 90° A-cod. with cable
PUR 12x0.14 bk UL/CSA+drag ch. 15m
Weight: 1.097 kg
Art.No.: 7000-19061-7051500

Contact Us for Availability
Move
M12 female 90° A-cod. with cable M12 female 90° A-cod. with cable
PUR 12x0.14 bk UL/CSA+drag ch. 20m
Weight: 1.456 kg
Art.No.: 7000-19061-7052000

Contact Us for Availability
15 m
20 m
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
A
A
PUR
PUR
12
12
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
30 V
30 V
30 V
30 V
30 V
30 V
30 V
30 V
1,5 A
1,5 A
M12 x 1
M12 x 1
inserted, screwed
inserted, screwed
3
3
0,8 kV
0,8 kV
I
I
Nickeled
Nickeled
nickel plated
nickel plated
Zinc die-casting
Zinc die-casting
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12)
DIN EN 61076-2-101 (M12)
705
705
black
black
cURus
cURus
1
1
3 wires twisted
3 wires twisted
1
1
9 wires around Stranding combination counter-rotating twisted
9 wires around Stranding combination counter-rotating twisted
Fleece
Fleece
gray-pink, violet, red-blue, (brown, red, gray, black, yellow, pink, green, white, blue)
gray-pink, violet, red-blue, (brown, red, gray, black, yellow, pink, green, white, blue)
5 m @ 25 °C
5 m @ 25 °C
45,1 g/m
45,1 g/m
PUR
PUR
92 ± 5 Shore A
92 ± 5 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
6 mm
6 mm
± 5 %
± 5 %
PP
PP
12
12
1 mm
1 mm
± 5 %
± 5 %
72 ± 3 Shore D
72 ± 3 Shore D
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
18
18
0,1 mm
0,1 mm
0,14 mm²
0,14 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
2 A
2 A
138 Ω/km @ 20 °C
138 Ω/km @ 20 °C
1,5 kV @ 60 s
1,5 kV @ 60 s
1,5 kV @ 60 s
1,5 kV @ 60 s
-40 °C
-40 °C
85 °C
85 °C
-25 °C
-25 °C
85 °C
85 °C
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
DIN EN ISO 4892-2 A
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
Good, application-related testing | DIN EN 60811-404
7,5 x Outer diameter
7,5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
2 Mio. @ 25 °C
2 Mio. @ 25 °C
2 Mio.
2 Mio.
± 180 °/m
± 180 °/m
35 cycles/min
35 cycles/min
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060311
27060311
27060311
27060311
27060311
27060311
27060311
27060311
EC001855
EC001855
1
1
85444290
85444290
4048879308328
4048879383738
* plus VAT, plus shipping