Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +43 1 706 45 25-0

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
Cable outlet:
Coding:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Mounting method:
Family construction form:
Thread:
Cable outlet:
Coding:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Current operating per contact max.:
Operating voltage DC max.:
Current operating per contact max.:
Industrial communication
Transfer parameters:
Data transmission rate max.:
Industrial communication | Ethernet functionality
duplex:
Installation | Connection
Mounting set:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Degree of protection (EN IEC 60529):
Mechanical data | Material data
Coating housing:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Mechanical data | Material data
Material housing:
Device protection | Electrical
Material group (IEC 60664-1):
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Mechanical data
Contour for corrugated hose:
Mechanical data | Material data
Coating locking:
Locking material:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
General data | Cable
Cable identification:
Cable Type:
Printing color of wire insulation:
Printing spacing of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Stranding factor min.:
Stranding factor max.:
Amount stranding (type 2):
Stranding (type 2):
Stranding factor min. (type 2):
Stranding factor max. (type 2):
Amount stranding (type 3):
Stranding (type 3):
Stranding factor min. (type 3):
Stranding factor max. (type 3):
Cable shielding (type):
Cable shielding (coverage):
Pair shielding (type):
Banding:
Filler:
Drain wire (type):
Drain wire (cross-section):
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material inner jacket:
Color (inner jacket):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Printing spacing of wire insulation:
Resistances wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Drain wire (cross-section):
Material conductor wire:
Conductor type (wire):
Electrical function wire:
Material wire insulation (Data):
Outer diameter wire insulation (Data):
Tolerance outer diameter wire insulation (data):
Shore hardness wire insulation (Data) :
Material properties wire insulation (Data):
Ingredient freeness wire insulation (Data):
Resistances wire insulation (Data):
Printing color wire insulation (data):
Printing spacing wire insulation (Data):
Amount wires (Data):
Amount strands wire (Data):
Diameter of single wires (Data):
Conductor crosssection wire (Data):
Material conductor wire (Data):
Wire conductor type (Data):
Electrical function wire (data):
Electrical data | Cable
Nominal voltage AC max.:
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Current load capacity min. Wire (Data):
Electrical function wire:
Electrical function wire (data):
Characteristic impedance:
Electrical resistance line constant wire:
Electrical resistance coating wire (Data):
AC withstand voltage (wire - wire):
Electric inductivity line constant:
Electric capacitance:
Electrical capacity line constant (wire - wire):
Electrical capacity line constant (wire - shield):
Power frequency withstand voltage (wire - jacket):
AC withstand voltage (wire - shield):
Transmission frequency range:
Cable
wire arrangement:
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Storage temperature min.:
Storage temperature max.:
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (installation):
Bending radius (fixed):
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Electrical data | Cable
Isolation resistance:
Connection data
Connection type 1
Family construction form:
No. of poles:
Connection type 2
Family construction form:
Gender:
Color contact carrier:
Coding:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
PIN 4:
PIN 5:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
GTIN:
Packaging unit:
customs tariff number:
Approvals
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Move
M12 male 0° / M12 male 0° D-cod. shielded M12 male 0° / M12 male 0° D-cod. shielded
PUR 1x4xAWG22 shielded gn UL/CSA+drag ch. 0.6m
Weight: 0.071 kg
Art.No.: 7000-44511-7960060

Available
Move
MVP-METALL, 4XM12, 5POLE, PRE-WIRED CABLE MVP-METALL, 4XM12, 5POLE, PRE-WIRED CABLE
3.0m PUR 8x0,34+3X0.75, UL/CSA
Weight: 0.7 kg
Art.No.: 8000-54515-3730300

Contact Us for Availability
0,6 m
-
0,6 Nm
-
inserted, screwed
-
M12
-
M12 x 1
-
straight
-
D
-
PUR
-
4
-
SW13
-
IP65, IP66K, IP67
-
0,6 Nm
-
inserted, screwed
-
M12
-
M12 x 1
-
straight
-
D
-
PUR
-
4
-
SW13
-
IP65, IP66K, IP67
-
-
48 V
-
48 V
-
4 A
60 V
-
1,5 A
-
CAT5e, Class D (ISO/IEC 11801:2002), (EN 50173-1)
-
100 MBit/s
-
Full duplex
-
-
M12 x 1
-
IP65, IP67, IP68
IP65, IP67, IP66K
-
-
Nickeled
inserted, screwed
-
3
-
1,5 kV
-
-
Zinc die-casting
I
-
-
Schraubgewinde
-
-25 °C
-
90 °C
-
depending on cable quality
without
-
Nickeled
-
Zinc die-casting
-
inserted, screwed, Shaking protection
-
-25 °C
-
85 °C
-
depending on cable quality
-
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
-
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
-
DIN EN 61076-2-101 (M12)
-
796
373
-
-
-
-
-
-
green
gray
cURus
cURus
1
1
4 wires around Core filler twisted
3 wires twisted
-
43 mm
-
43 mm
-
1
-
8 wires around Stranding combination counter-rotating twisted
-
90 mm
-
90 mm
-
-
-
-
-
-
-
-
copper braid, tinned
copper braid, tinned
85 %
80 %
-
-
Fleece, Foil
Fleece, Foil
yes
-
-
-
-
-
white, yellow, blue, orange
yellow, white, green, (blue, brown, green-yellow, gray, gray-pink, red-blue, green-white, brown-green)
69,3 g/m
145,2 g/m
PUR
PUR
89 Shore A
85 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free, LABS-free
6,7 mm
9,3 mm
± 5 %
± 5 %
FRNC
-
natur
-
PE
TPE-E
4
8
1,4 mm
1,4 mm
± 5 %
± 5 %
65 Shore D
55 Shore D
-
-
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free, silicone-free, LABS-free
-
-
-
-
-
-
7
42
22 AWG
0,1 mm
22 AWG
0,34 mm²
-
-
Stranded copper wire, bare
Stranded copper wire, bare
-
strand class 6
-
-
-
TPE-E
-
1,8 mm
-
± 5 %
-
55 Shore D
-
-
-
lead-free, CFC-free, halogen-free, silicone-free, LABS-free
-
-
-
-
-
-
-
3
-
96
-
0,1 mm
-
0,75 mm²
-
Stranded copper wire, bare
-
strand class 6
-
-
300 V
-
-
500 V
-
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,8 A
4 A
-
12 A
-
-
-
-
100 Ω ± 15 % @ 100 MHz
-
55 Ω/km @ 20 °C
53 Ω/km @ 20 °C
-
26 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
-
-
-
-
50000 pF/km
-
-
-
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-
-
white, yellow, blue, orange
-
-40 °C
-40 °C
80 °C
90 °C
-30 °C
-40 °C
70 °C
90 °C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
IEC 60332-2-2 | UL 1581 § 1090 | UL 1581 § 1100 FT2
UL 1581 § 1090 | IEC 60332-2-2 | UL 1581 § 1100 FT2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
Good, application-related testing | DIN EN 60811-404
-
x Outer diameter
5 x Outer diameter
x Outer diameter
12 x Outer diameter
12 x Outer diameter
3 Mio. @ 25 °C
5 Mio.
5 m @ 25 °C
-
3,3 m/s @ 25 °C
2 m/s
1 Mio. 25 °C
-
± 180 °/m
-
-
-
5000 MΩ × km
-
-
free cable end
-
16
-
M12
-
female
-
black
-
A
-
5
-
+
-
NC S 2
-
-
-
NO S 1
-
PE
27061801
27279219
27060307
27279219
27060307
27279219
27060307
27279219
27060307
27440108
27060307
27440108
27060307
27440108
27060307
27440108
EC002599
EC002585
4048879141369
4048879351713
1
1
85444290
85444290
-
-
-
* plus VAT, plus shipping