MVK Fusion
MVK PN FDI6/3 FDO2/1 DIO4 IOL2 IRT PP
Art.No.: | 55510 |
Weight: | 1.4 kg |
Country of origin: | DE |
Available
Description
safe inputs/outputs up to cat.4/PLe (EN ISO 13849-1), up to SIL3 (IEC 61508), up to SILCL3 (IEC 62061)
Double safety output port
FDI6/3 FDO2/1 DIO4 IOL2 (IRT)
Ethernet 10/100 Mbit/s; Push Pull RJ45 Data connector
Push Pull Power connector, max. 16 A
M12, 5-pole, A-coded
Galvanic isolation
Connection cables are in the online shop under "Connection Technology".
Housing fully potted.
Double safety output port
FDI6/3 FDO2/1 DIO4 IOL2 (IRT)
Ethernet 10/100 Mbit/s; Push Pull RJ45 Data connector
Push Pull Power connector, max. 16 A
M12, 5-pole, A-coded
Galvanic isolation
Connection cables are in the online shop under "Connection Technology".
Housing fully potted.






Technical Data
Input
Sensor supply US | 24 V DC (EN 61131-2), max. 700 mA (M12 female), short-circuit and overload protected |
---|---|
Type | for 3-wire sensors or mechanical switches, PNP, IO-Link Devices |
Output
Actuator supply UA | 24 V DC (EN 61131-2), max. 8 A |
---|---|
Switching current per output | max. 2 A (short-circuit and overload protected) |
General data
Mounting method | 2-hole screw mounting |
---|---|
Temperature range | -20...+60 °C (storage temperature -40...+85 °C) |
Protection | IP67 |
Dimensions H×W×D | 51.2×63×225 mm |
Diagnostic
Communication status | via LED |
---|---|
Diagnostic via BUS | per module and channel |
Diagnostic via LED | per module and channel |
Actuator warning | per channel via LED and BUS |
Monitoring - under voltage | yes |
Monitoring - no voltage | yes |
Short-circuit and overload | yes |
Cross-link detection | Sensor/Actuator |
Wire break detection | yes |
IO-Link
Specification | IO-Link Master V1.1.2 |
---|---|
Port Class | 1× Class A; 1× Class B (galvanically separated) |
IO-Link | 2× Master |
Transfer parameters | 32 Byte (In) 32 Byte (Out) per IO-Link port |
Operating modes | COM1; COM2; COM3 (automatic) |
PROFINET
Specification | V2.3, Conformance Class C (IRT) |
---|---|
Addressing | DCP |
PROFINET Netload Class | III |
MRP | yes |
Shared Device | yes, for 2 controls |
Connections
Fieldbus | Ethernet 10/100 Mbit/s; Push Pull RJ45 Data connector |
---|---|
Sensor-system/actuator supply | Push Pull Power connector, max. 16 A |
I/O ports | M12, 5-pole, A-coded |
Parameterization
PIN 4 | Input/Output (port X4, X5); Input (port X6, X7) |
---|---|
PIN 2 | Input/Output (port X4, X5); Input (port X6) |
Safety Indicators
Service life | 20 years |
---|---|
Category | X0, X1, X2, X3 up to 4, X7 (PIN 3) up to 3 |
PFH | IEC 62061: 4.8E-9 1/h; IEC 61508: 7.8E-10 1/h |
PL | X0, X1, X2, X3 up to e, X7 (PIN 3) up to d |
SIL CL | up to 3 |
SIL | X0, X1, X2, X3 up to 3, X7 (PIN 3) up to 2 |
Commercial data
ECLASS-6.1 | 27242604 |
---|---|
ECLASS-7.0 | 27242604 |
ECLASS-8.0 | 27242604 |
ECLASS-9.0 | 27242604 |
ECLASS-10.1 | 27242604 |
ECLASS-11.1 | 27242604 |
ECLASS-12.0 | 27242604 |
customs tariff number | 85389099 |
EAN | 4048879714983 |
Packaging unit | 1 |
Accessories
---- Emergency Stop Button ----
---- Button ----
---- Sensor-Actuator Adapter ----
---- Power-Cable ----
---- Heat Sink ----
---- Screw Plug ----
---- Device Marker ----
---- Digital I/O Module ----