You might also like
DeviceNet, CANopen
Female straight
M12, 5-pole
A-coded
Plastic housings with good resistance against chemicals and oils.
The resistance to aggressive media should be individually tested for your application. Further details on request.
Further cable lengths on request.
Female straight
M12, 5-pole
A-coded
Plastic housings with good resistance against chemicals and oils.
The resistance to aggressive media should be individually tested for your application. Further details on request.
Further cable lengths on request.
Form
Form | 13225 |
---|
Technical Data
Operating voltage | max. 60 V AC/DC |
---|---|
Operating voltage (only UL listed) | max. 30 V AC/DC |
Rated surge voltage | 1.5 kV |
Operating current per contact | max. 4 A |
Material group | IEC 60664-1, category I |
Coding | A-coded |
Locking of ports | Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing |
Compression gland | M12 (SW13) |
Protection | IP65, IP66K, IP67 inserted and tightened (EN 60529) |
Locking material | Zinc die casting, matte nickel plated |
Material | PUR |
suitable for corrugated tube (internal Ø) | without |
General data
Standards | DIN EN 61076-2-101 (M12) |
---|---|
Pollution Degree | 3 |
Stripping length (jacket) | 20 mm |
Temperature range | -25...+85 °C, depending on cable quality |
Material (gasket) | FKM |
Cables
No./diameter of wires | 2× 0.25 + 2× 0.34 mm² |
---|---|
Wire isolation | PE (rd, bk), (bl, wh) |
Material (jacket) | PUR (UL/CSA) |
Outer Ø | 6.9 mm ±5% |
Bend radius (moving) | 10× outer Ø |
Temperature range (fixed) | -40...+80 °C |
Temperature range (mobile) | -30...+70 °C |
Cable identification | 834 |
Approval (cable) | UL (AWM-Style 20233/10578), CSA; CE |
Cable weight [g/m] | 63,12 |
Material (wire) | Cu wire, tin plated |
Resistor (core) | max. 78 Ω/km (data pair, max. 54 Ω/km (power pair); (20 °C) |
Diameter (core) | 2× 0.25 + 2× 0.34 mm² |
AWG | similar to AWG 24 (0.25 mm²); similar to AWG 22 (0.34 mm²) |
Wire-Ø incl. isolation | 2.1 mm ±5% (0.25 mm²); 1.5 mm ±5% (0.34 mm²) |
Color/numbering of wires | wh, bl (data pair); bk, rd (power pair) |
Shield | yes |
optical shield cover | min. 65% |
Material (jacket) | PUR |
Outer-Ø (jacket) | 6.9 mm ±5% |
Color (jacket) | blue |
chemical resistance | good resistance to oil, gasoline and chemicals |
thermal resistance | flame retardant |
Nominal voltage | 300 V |
Temperature range (fixed) | -40...+80 °C |
Temperature range (mobile) | -30...+70 °C |
Bend radius (fixed) | 6× outer Ø |
Bend radius (moving) | 10× outer Ø |
Traversing distance (C-track) | max. 5 m (horizontal) |
Travel speed (C-track) | max. 3 m/s |
Acceleration (C-track) | max. 5 m/s² |
Jacket Color | blue |
Commercial data
country of origin | DE |
---|---|
customs tariff number | 85444290 |
EAN | 4048879668149 |
eClass | 27279218 |
Packaging unit | 1 |

* only for products with UL/CSA approved cable