Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +43 1 706 45 25-0
Zoom
M12 FEMALE 0° SHIELDED, B CODED ,INTERBUS
Product may differ from image

M12 FEMALE 0° SHIELDED, B CODED ,INTERBUS

PUR 3x2x0.25 shielded violet 50m
Art.No.: 7000-14261-7995000
Weight: 3.841 kg
  In production
 Product Comparison
List price per piece:

You might also like

Interbus
Female straight
M12, 5-pole
B-coded
shielded
Further cable lengths on request. Plastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request.
Form
Form 14261
Cables
No./diameter of wires 3× (2× AWG24)
Wire isolation PE (whbr, grpk, gnye)
C-track properties 2 Mio.
Material (jacket) PUR
Outer Ø 7.7 mm ±5%
Bend radius (moving) 15× outer Ø
Temperature range (fixed) -40...+70 °C
Temperature range (mobile) -30...+70 °C
Cable identification 799
Approval (cable) Interbus (DIN 19258/EN50254/IEC 61158 conform)
Cable weight [g/m] 76,49
Material (wire) Cu wire, bare
Resistor (core) max. 96 Ω/km (20°C)
Single wire Ø (core) 0.1 mm
Construction (core) 32× 0.1 mm (multi-strand wire class 6)
Diameter (core) 3× (2× AWG24)
AWG similar to AWG 24
Material (wire isolation) PE
Shore hardness (wire isolation) 55 ±5 D
Wire-Ø incl. isolation 1.4 mm ±5%
Color/numbering of wires (wh, br) + (gr, pk) + (gn, ye)
Shield yes
min. 85%
Material (jacket) PUR
Material property (jacket) CFC-, halogen- and cadmium-free, matt, low-adhesion, machine easy to process, abrasion-resistant
Shore hardness (jacket) 85 ±5 A
Outer-Ø (jacket) 7.7 mm ±5%
Color (jacket) violet
chemical resistance good resistance to oil, gasoline and chemicals (VDE 0472 Teil 803/VDE 0249)
Nominal voltage 250 V AC
Test voltage 1500 V (wire/wire); 1000 V (wire/shield)
Temperature range (fixed) -40...+80 °C
Temperature range (mobile) -30...+70 °C
Bend radius (fixed) 6× outer Ø
Bend radius (moving) 12× outer Ø
No. of bending cycles (C-track) max. 2 Mio. (25 °C)
Traversing distance (C-track) max. 5 m (horizontal)
Travel speed (C-track) max. 3 m/s
Acceleration (C-track) max. 3 m/s²
Jacket Color violet
Technical Data
Operating voltage max. 60 V AC/DC
Rated surge voltage 1.5 kV
Operating current per contact max. 4 A
Material group IEC 60664-1, category I
No. of poles 5
Coding B-coded
Locking of ports Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing
Compression gland M12 (SW13)
Protection IP67 inserted and tightened (EN 60529)
Locking material Zinc die casting, matte nickel plated
General data
Pollution Degree 3
Temperature range -25...+85 °C, depending on cable quality
Commercial data
country of origin DE
customs tariff number 85444290
EAN 4048879197564
eClass 27061801
Packaging unit 1
 
Data Regarding Article:
  • Download Data Sheet
  • Download Approvals and certificates 7000-13061_08-09.19_ce_z_b.pdf
  • Download China RoHS information EPUP-E_CHR_x_1.pdf
cCSAus
Interbus